Warning · Error handling
If waiter registration takes more than 10 seconds, the setter raises before signalling cancellation, but the test awaits only the poll and merely calls `task.cancel()` during cleanup.
Impact
The test can poll toward its 100-second deadline and log an unretrieved task exception instead of reporting the registration timeout promptly.
Recommended action
Supervise both tasks so setter failure aborts polling, and await both tasks during cleanup.