How do we catch configuration changes that are incompatible with production?

Compare the version of the application that reads a setting with the configuration each target supplies. Check names, types, defaults, and when a missing value becomes an error.

Try the upgrade in both directions#

A worker might change a timeout from seconds to milliseconds while keeping the key REQUEST_TIMEOUT. Both versions accept the integer 30. One waits thirty seconds and the other waits thirty milliseconds. A presence check will pass in both cases. Trace the value to the timer and compare it with the documented unit.

Consider introducing a new key that includes the unit. Test old and new configuration during rollout, including rollback to the previous binary. Use key names or a synthetic value when demonstrating the failure. A secret's contents are unnecessary for checking its binding name. Terraform configuration validation · Proofline coverage and availability